Product Overview
 

The Kinee ACB Series (Air Circuit Breaker) is engineered for low-voltage power distribution networks with rated operational currents from 400A to 6300A and a rated operational voltage up to AC 690V. Positioned as the primary incoming or outgoing protective device in main switchgear assemblies, it safeguards high-capacity electrical systems against overloads, short-circuits, and undervoltage faults. Designed for seamless integration into industrial power panels, commercial distribution boards, and infrastructure substations, this series complies strictly with IEC 60947-2 standards, ensuring reliable arc extinction and fault clearance under severe short-circuit conditions.

 

 
 
Key Features & Benefits

High Breaking Capacity

Delivers ultimate short-circuit breaking capacities (Icu) up to 120kA at AC 415V, ensuring rapid fault clearing before thermal and dynamic stress damages downstream assets.

Intelligent Microprocessor Trip Units

Equipped with advanced digital controllers offering programmable protection curves (LSI/LSIG), real-time phase current metering, fault event logging, and harmonic analysis.

Modular Auxiliary Interface

Features standard plug-in auxiliary contacts, motorized charging mechanisms, and shunt/closing releases pre-wired to terminal blocks for straightforward control circuit integration.

Clear Safety Isolation

Provides a visible physical isolation gap and mechanical interlocking provisions to secure maintenance personnel during lockout/tagout (LOTO) procedures.

 

Technical Specifications

 

Technical Parameter

Specification Range / Value

Standards Compliance

IEC 60947-2, GB/T 14048.2

Rated Operational Voltage (Ue)

AC 415V / 690V

Rated Current (In)

400A – 6300A (Split into 3 frame sizes: 1600A, 2500/3200A, 4000/6300A)

Number of Poles

3P / 4P

Ultimate Short-Circuit Breaking Capacity (Icu)

50kA to 120kA (at AC 415V)

Service Short-Circuit Breaking Capacity (Ics)

100% x Icu (Select models)

Rated Insulation Voltage (Ui)

AC 1000V

Trip Unit Type

Microprocessor-based (LCD/LED digital display with Modbus/Profibus communication)

Mounting Type

Draw-out type (Withdrawable) & Fixed type

Mechanical Life (Operations)

15,000 to 20,000 cycles

Electrical Life (Operations)

1,000 to 3,000 cycles

 

Product Types & Configuration Architecture

 

high-capacity-breakers-air-circuit-breakerd8541

Fixed Type ACB

Engineering Detail: Bolted directly into the switchgear compartment busbars. Recommended for cost-sensitive installations where scheduled downtime for maintenance is acceptable and spatial depth is limited.

high-capacity-breakers-air-circuit-breaker202606180834310265b

Draw-out Type (Withdrawable) ACB

Engineering Detail: Comprises a breaker body and a rigid cassette chassis equipped with safety shutters and a 3-position racking mechanism (Connect, Test, Disconnect). Allows the breaker body to be safely extracted for servicing without de-energizing the main switchgear bus.

high-capacity-breakers-air-circuit-breaker20260618083430374da

Specialized Application Variants

Tropicalized variants with anti-humidity coatings for marine/offshore environments; DC-optimized configurations tailored for heavy-duty industrial DC distribution buses.

 

Applications
 

Main Switchgear & Power Distribution Panels

Deployed as the main incoming breaker in low-voltage switchboards of industrial manufacturing plants.

Commercial Buildings & Data Centers

Provides continuous, selective protection for high-density load centers, preventing cascading power outages.

Infrastructure & Utilities

Installed in municipal water treatment facilities, airports, and railway traction power distribution systems.

Renewable Energy Systems

Utilized on the low-voltage side of wind turbine generator transformers and large-scale solar photovoltaic inverter combining stations.

 

Quality Control & Certifications

 

high-capacity-breakers-air-circuit-breakerd8541

Type Testing

Every frame size undergoes rigorous short-circuit breaking tests, temperature-rise verification, and dielectric strength tests certified by independent international laboratories.

 
high-capacity-breakers-air-circuit-breaker202606180834317e067

Material Traceability

Main contact tips utilize high-purity silver-tungsten (AgW) composite materials welded via precision resistance brazing to minimize contact resistance and thermal aging.

 
high-capacity-breakers-air-circuit-breaker20260618083430374da

Routine Factory Calibration

100% automated calibration of overcurrent release characteristics using secondary injection testing equipment to guarantee tripping time accuracy within plus or minus 5%.

 
high-capacity-breakers-air-circuit-breaker202606180834310265b

Certifications

Manufactured under an ISO 9001 quality management system; products carry CE and IEC 60947-2 compliance documentation.

 

 

 
 
OEM & Customization
01.

Busbar Terminal Adaptations

Custom horizontal, vertical, or mixed busbar connection terminals engineered to match specific panel enclosure layouts.

02.

Control Voltage Options

Control coils and motor operators available in DC 24V, AC/DC 110V, and AC/DC 220V configurations.

03.

Communication Protocols

Integration of optional RS485 communication modules supporting Modbus-RTU protocol for SCADA and Power Management Systems (PMS).

04.

Private Labeling

Laser-etched nameplates, customized carton labeling, and tailored operation manual documentation for qualified distribution partners.

 

Installation & Compatibility

 

 

Clearance Requirements

Detailed dimensional drawings provided for minimum arc-chute clearance and phase-to-phase insulation distances inside the cabinet.

 

Mechanical Interlocks

Compatible with standard door interlocks, key lock provisions (Profalux/Ronis), and cable mechanical interlocking between multiple supply sources (ATS configurations).

 

Environment Conditions

Designed for operation in ambient temperatures from -5°C to +40°C (derating applies above +40°C); relative humidity up to 95% at +20°C.

 

 

Packaging & Shipping

Export-Grade Protection

Secured within custom-built fumigation-free wooden crates featuring internal shock-absorbing foam wedges and moisture-barrier vacuum-sealed polyethylene wrapping.

Accessories Packing

Trip unit manuals, secondary plug connectors, and racking handles securely packed in independent sub-boxes labeled with barcode identifiers.

Logistics Support

Compatible with standard container shipping (FCL/LCL) and air freight; complete with hazardous-free material declarations and commercial shipping documents (Certificate of Origin, Bill of Lading, Test Reports).

 

 

Frequently Asked Questions

 

Q: What lead time can we expect for standard orders and customized OEM batch production?

A: Standard stock configurations (such as 1600A and 2500A 3P draw-out units) typically ship within 7 to 14 business days. Customized production batches involving specialized busbar drilling, specific control coil voltages, or private-label branding generally require 20 to 30 calendar days depending on order volume.

Q: How do you ensure the calibration accuracy of the electronic trip units before delivery?

A: Every single circuit breaker undergoes automated computer-controlled secondary current injection testing prior to packaging. The test simulates overload, short-circuit, and ground-fault conditions to verify that the tripping time curves strictly adhere to IEC 60947-2 tolerance windows. Individual test reports can be supplied upon request.

Q: Are Kinee ACBs fully certified for international project bidding and local compliance?

A: Yes. Our ACB series is tested and certified according to IEC 60947-2 standards and carries CE conformity. We provide complete third-party test reports, CB certificates, and ISO 9001 quality documentation to ensure smooth customs clearance and compliance with local engineering inspection approvals.

Q: What spare parts or maintenance components should we stock for long-term operations?

A: For routine facility maintenance, we recommend stocking secondary control plugs, shunt trip coils, closing coils, and auxiliary contact blocks. For units deployed in harsh dusty or high-frequency switching environments, replacement arc chutes and main contact inspection kits can be ordered directly from our parts catalog.

 

modular-1
Request a Quote & Engineering Resources

Need 3D STEP CAD models, dimensional layout drawings, or a formal commercial quotation for your switchgear project? Connect with our engineering sales team.
Email: patti@kinee.net.cn
Inquiry Checklist: To accelerate your technical and commercial response within 24 hours, please include:
Rated Current (In) & Frame Size
Pole Configuration (3P / 4P)
Mounting Type (Fixed / Draw-out)
Control Coil Voltage & Destination Port

Wenzhou Kinee Electrical Co., Ltd. is one of the most professional acb manufacturers and suppliers in China, featured by quality products and good price. Please rest assured to buy advanced acb made in China here from our factory. We also accept customized orders.

Send Inquiry