High Performance AC ContactorsModel: KNX3-H series. Rated insulation voltage: 690V. Rated operating voltage: 660/690V. Rated operating current: 95A. Mechanical life (cycles/hour): 3600. Temperature Range: -5°C to +40°C.
-
Multifunctional Contactor AC Magnetic ContactorModel: KNX8GN series. Rated voltage: 660V. Rated current: 9-85A. Uimp: 6kV. Frequency: 50/60Hz.
-
AC220V 3P Magnetic ContactorModel: KNX8C series. Rated voltage: 660V. Rated current: 9-85A. Uimp: 6kV. Frequency: 50/60Hz.
-
Three Phase Magnetic AC ContactorModel:KNX8G series. Rated voltage: 660V. Rated current: 9-85A. Uimp: 6kV. Frequency: 50/60Hz.
-
High Quality AC Contactor 690VModel:KNX2-H series. Rated operating current: 9-95A. Rated operating voltage: 220V~690V. Rated insulation voltage: 690V. Number of poles: 3P. Installation method: Rail mounting and screw mounting.
-
Electrical AC Contactor All-copper CoilModel:KNX2 series. Rated operating current: 9-95A. Rated operating voltage: 220V~690V. Rated insulation voltage: 690V. Standards: IEC 60947-1, IEC 60947-4-1.
-
3P Motor Protection Circuit BreakerModel:KNV3ME40. Ui: 690V. Rated Power: 4kW-45kW. Current: 0.16-80A. Control Ciruit Voltage: 24V-440V. Division capacity: 10-100KA. Frequency: 50/60Hz.
-
Thermomagnetic Motor Protection Circuit BreakerModel:KNV2PM20. Ui: 690V. Rated Power: 4kW-45kW. Current: 0.16-80A. Control Ciruit Voltage: 24V-440V. Division capacity: 10-100KA. Frequency: 50/60Hz.
-
Motor Protection Circuit BreakerProduct Model: KNV2ME14. Product Application: Motor Protection. Trip Type: Thermomagnetic. Connection Type: AC. Network Frequency: 50/60 Hz. Rated Current [In]: 6.3 A. Thermal Overload Protection
WebA contactor is an electrical device which is used for switching an electrical circuit on or off. It is considered to be a special type of relay. However, the basic difference between the...
WebMar 17, 2021 · A contactor is a component used to switch an electrical circuit on or off. It is considered to be part of the relay family, but the main difference is that they are used for...
WebConnection between PLC and Contactor. As seen in the image above, the contactor has three connections – a three-phase power supply, a contact for energizing it, and a contact for giving feedback...
WebMay 29, 2018 · The contactor on your A/C unit is basically a switch that allows or prevents power to the unit. While there is always power at the unit (assuming everything else is working...
WebMay 3, 2023 · Three other elements that ought to be considered when choosing a contactor are its main. contacts, auxiliary contacts and the coil. The main contacts carry the current, while...
WebProduct Details NEMA Contactors Our motor-rated contactors are available from NEMA size 00…9, in open and enclosed design for full-voltage starting of AC motors. Our contactors can also be used...