Motor Protection Circuit BreakerProduct Model: KNV2ME14. Product Application: Motor Protection. Trip Type: Thermomagnetic. Connection Type: AC. Network Frequency: 50/60 Hz. Rated Current [In]: 6.3 A. Thermal Overload Protection
-
Multifunctional Contactor AC Magnetic ContactorModel: KNX8GN series. Rated voltage: 660V. Rated current: 9-85A. Uimp: 6kV. Frequency: 50/60Hz.
-
AC220V 3P Magnetic ContactorModel: KNX8C series. Rated voltage: 660V. Rated current: 9-85A. Uimp: 6kV. Frequency: 50/60Hz.
-
Three Phase Magnetic AC ContactorModel:KNX8G series. Rated voltage: 660V. Rated current: 9-85A. Uimp: 6kV. Frequency: 50/60Hz.
-
AC Contactor Motor Magnetic ContactorModel:KNX3 series. Poles: 3P. Rated operating current: 9-95A. Rated operating voltage: 220V~690V. Rated insulation voltage: 690V. Installation method: Rail mounting and screw mounting.
-
High Quality AC Contactor 690VModel:KNX2-H series. Rated operating current: 9-95A. Rated operating voltage: 220V~690V. Rated insulation voltage: 690V. Number of poles: 3P. Installation method: Rail mounting and screw mounting.
-
Electrical AC Contactor All-copper CoilModel:KNX2 series. Rated operating current: 9-95A. Rated operating voltage: 220V~690V. Rated insulation voltage: 690V. Standards: IEC 60947-1, IEC 60947-4-1.
-
Thermomagnetic Motor Protection Circuit BreakerModel:KNV2PM20. Ui: 690V. Rated Power: 4kW-45kW. Current: 0.16-80A. Control Ciruit Voltage: 24V-440V. Division capacity: 10-100KA. Frequency: 50/60Hz.
-
High Performance AC ContactorsModel: KNX3-H series. Rated insulation voltage: 690V. Rated operating voltage: 660/690V. Rated operating current: 95A. Mechanical life (cycles/hour): 3600. Temperature Range: -5°C to +40°C.
Secure your uptime by letting the AF technology overbridge voltage drops and sags. Main features Up to 560 kW - 400 V AC-3, 900 hp - 480 V and 2850 A - 690 V AC-1, 2850 A - general use Only 4 coils...
Magnetic Contactor & Overload Magnetic Contactor Magnetic Contactor 359 items Sort By -23% 5.5KW, 12A (AC3), 3P, 1NO + 0NC, 230V AC; Size - S00 - Siemens ৳1,800.00 ৳2,350.00 -33% 9KW, 18A (AC3), 3P,...
Jan 22, 2018 · This directs the current through from L2 and directs it through the 3 rd phase on the contactor and overload (L3 & T3). Then you connect the 2 motor leads to T1 and T3. Using this...
Magnetic Contactor. TECO electromagnetic contactor (7-630A), the full range of design meets IEC standards, the shell is made of UL-certified flame retardant V-0 engineering plastics, with...
˙ When motor needs emergency stop during operation, it is possible to stop the motor by cutting off its contact from the magnetic contact with test button. ˙In order to test the operation of thermal...
MAGNETIC CONTACTORS & OVERLOAD RELAYS. Globalization of Technology. Magnetic Contactors & Overload Relays t Various Product Ranges: 9 - 800 A (8 frames) t Rated...