3P Motor Protection Circuit BreakerModel:KNV3ME40. Ui: 690V. Rated Power: 4kW-45kW. Current: 0.16-80A. Control Ciruit Voltage: 24V-440V. Division capacity: 10-100KA. Frequency: 50/60Hz.
-
Multifunctional Contactor AC Magnetic ContactorModel: KNX8GN series. Rated voltage: 660V. Rated current: 9-85A. Uimp: 6kV. Frequency: 50/60Hz.
-
AC220V 3P Magnetic ContactorModel: KNX8C series. Rated voltage: 660V. Rated current: 9-85A. Uimp: 6kV. Frequency: 50/60Hz.
-
Three Phase Magnetic AC ContactorModel:KNX8G series. Rated voltage: 660V. Rated current: 9-85A. Uimp: 6kV. Frequency: 50/60Hz.
-
AC Contactor Motor Magnetic ContactorModel:KNX3 series. Poles: 3P. Rated operating current: 9-95A. Rated operating voltage: 220V~690V. Rated insulation voltage: 690V. Installation method: Rail mounting and screw mounting.
-
Electrical AC Contactor All-copper CoilModel:KNX2 series. Rated operating current: 9-95A. Rated operating voltage: 220V~690V. Rated insulation voltage: 690V. Standards: IEC 60947-1, IEC 60947-4-1.
-
Thermomagnetic Motor Protection Circuit BreakerModel:KNV2PM20. Ui: 690V. Rated Power: 4kW-45kW. Current: 0.16-80A. Control Ciruit Voltage: 24V-440V. Division capacity: 10-100KA. Frequency: 50/60Hz.
-
Motor Protection Circuit BreakerProduct Model: KNV2ME14. Product Application: Motor Protection. Trip Type: Thermomagnetic. Connection Type: AC. Network Frequency: 50/60 Hz. Rated Current [In]: 6.3 A. Thermal Overload Protection
-
High Performance AC ContactorsModel: KNX3-H series. Rated insulation voltage: 690V. Rated operating voltage: 660/690V. Rated operating current: 95A. Mechanical life (cycles/hour): 3600. Temperature Range: -5°C to +40°C.
A reduction of the coil's energy consumption by 80% lets you save energy Secure your uptime by letting the AF technology overbridge voltage drops and sags. Main features Up to 560 kW - 400 V AC-3,...
10/23/2017 · Contactor Coil Voltage. You should next confirm the control voltage to be used to power the contactor. This can be the same as the line voltage, however often a lower voltage is selected...
hybridpowercorp.com...
230-440 V. Frequency. 50-60 Hz. Model Number. LC1D32. Current. 2Amp-100Amp. With an objective to fulfill the demands of our clients, we are engaged in providing a wide array of Schneider LC1D32 Power...
Our electrical contactors are typically fitted with a normally open (NO) contact and they suppress the arc that is produced when interrupting heavy motor currents. Electrical contactors can handle...
13A Solid State Relay. 13A switching at 125C for 2.5 million cycles and features like short circuit, reverse battery, and load dump protection built in. This solid state solution is made to work in...